Seitenansicht 16
PROBLEM? 17
Do not HESITATE to call us via our assistance hotline (at the end of the notice). Our technicians will have the pleasure to
help you make a perfect installation.
If the Control Panel doesn’t receive the
Supervisory signals transmitted from a certain
PIR, an “Out-Of-Order” fault message will be
generated.
z Sleep Timer
The PIR has a “sleep time” of approximately 1
minute to conserve power. After transmitting a
detected movement, the PIR will not retransmit
for 1 minute; any further movement detected
during this sleep period will extend the sleep
time by another minute. In this way continuous
movement in front of a PIR will not unduly
exhaust the battery.
z Test mode
The PIR can be put into Test mode by pressing
the Test Button aka LED on the front cover. In
Test mode, it will disable the sleep timer and will
enable the LED indicator to flash every time a
movement is detected. Each time press the Test
Button, the PIR will transmit a test signal to the
Control Panel for radio range test and enter the
test mode for 3 mins. It will exit Test Mode
automatically after 3 mins and returns to normal
mode.
z LED Indicator
In Normal operation mode, the LED Indicator
will not light except in the following situations:
z When the PIR is in low battery condition,
every time it transmits a detected
movement, the LED will light up for about
2 seconds.
z When the cover is opened and the tamper
switch is violated, the LED will light up for
2 sec. to indicate it is transmitting the
Tamper” signal.
z When the Tamper condition persists, every
time it transmits a detected movement, the
LED will light up.
However, if the PIR is in Test mode, the LED
will light up every time a movement is detected.
z Battery
z The PIR uses one 3.6 V Lithium battery as
its power source. The PIR will have a
typical battery life of 5 years at an average
of 20 activations a day.
z Low battery detection operates at a
threshold of 3.2V+/-2.4% where the PIR has
enough reserve energy to typically operate
for 1 month before complete exhaustion. A
low battery signal will be sent to the Control
Panel along with regular signal
transmissions for the Control Panel to
display the status accordingly.
z For each installation, the battery is installed
in by the factory before shipment with an
Insulator inserted.
z Getting Started
z Pull out the battery Insulator steadily.
z The LED indicator steadily flashes for 30
seconds. (The PIR is warming up). During
the warming period, the PIR will not be
activated. It is recommended that you stay
away from the detection area during this
time. After the warming period is over, the
light will turn off and the PIR will be ready
for operation.
z The Control Panel is already into “Device
+/-“ menu and then select “Add Device”
menu.
z Press the test buttons on the front cover.
Step B5. After the detected PIR Detector is
confirmed, you are requested to choose
between “Burglar”, “Home Omit”,
“Entry”, “Home Delaydevice mode.
B u r g l a r
Home O m i t
Ent r y
Home D e l ay
<
<
N
N
O
O
T
T
E
E
>
>
For detailed functional descriptions of
PIR Detector in these 4 different device
modes, please refer to the Note section
following Step A5 for adding Door
Contact.
) “B” for Burglar PIR Detector
) “O” for Home Omit PIR Detector
) “E” for Entry PIR Detector
) “D” for Home Delay PIR Detector
StepB6. Make a selection and press “OK”. The
screen will then prompt you to select the
Instant attribute if the selected device
mode supports the option.
I n s t a n t O f f
I n s t a n t O n
<
<
N
N
O
O
T
T
E
E
>
>
For detailed functional descriptions of
PIR Detector with or without the Instant
attribute, please refer to the Note section
Seitenansicht 16